http://www.fobsun.com     sales@fobsun.com

Fobsun

User's Manual for LED T8 Tube Lights

This manual includes important information about checking after receiving the product, cautions, working environment of the product, user's responsibilities and malfunction explanations, please read it carefully before you use the product.

Product Checking

1) Unpack and carefully examine the product.
2) Report any damage and save all packing material if any part is damaged during the transportation.
3) Do not attempt to use this device if it is damaged.

Cautions

1) This device shall be installed and operated by a qualified electrician or technician in accordance with all relevant local codes.
2) Risk of electric shock. Ensure that the power supply is off when wiring or soldering the sections of the device.
3) Do not use sharp tools near or on the surface of the device.
4) Suggested continuous working time is around 8 hours, no more than 14 hours. To get longer lifespan and better performance, we suggest not light up for 24 hours or above continuously, otherwise there will be faster brightness loss and shorter lifetime.
5) The ambient temperature shall be limited from -20 to 40 degree Celsius.
6) The input voltage shall be 110/220V AC, 50/60Hz or 220-240V AC, 50/60Hz, which depends on local voltage.
7) The tubes shall be used or stored in dry places, where ambient humidity is limited to 10-70% RH and no corrosive gases exist. If the tubes are used for outdoor applications, waterproof holders and covers are needed.
8) The tubes shall not be exposed to high interference caused by the magnetic or electric fields, which is subject to the standards of CE.
9) The tubes shall be disassembled or repaired without the permission of FOBSUN Electronics.

Working Environment

This product is suitable for indoor use, and applicable for dry environment.

User Responsibilities

It is the responsibility of the contractor, installer, purchaser, owner, and user to install, maintain, and operate the device in such a manner as to comply with all state and local laws, ordinances, and regulations.
Note: The instructions and precautions set forth in this user guide are not necessarily all-inclusive, all conceivable, or relevant to all applications, FOBSUN Electronics cannot anticipate all conceivable or unique situations.

Malfunction Explanations

These LED tubes ˇ°DO NOTˇ± require a ballast or starter, which is required for traditional standard fluorescent tubes. If the ballast and starter is connected to the LED tube it will overdrive the LED tube when starting and under drive it afterwards causing malfunctions in the LED tube itself.
1. Can not light on
1) Be sure there has the correct AC source connected.
2) And then sure that there has correct AC voltage shows on the terminals.
3) If still can not light on, please contact your local deal.
2. Abnormal condition such as: smoking, odor, flicker, noising
1) Shut off AC power source immediately.
2) Please contact your local deal as soon as possible.

Appendix: Energy Saving Comparison Sheet

 

1200mm LED T8 Tube Light

1200mm Fluorescent

Savings

Power

22 Watts

45 Watts

 

Ballast Power

no ballast

15 Watts

38 Watts

Daily Usage

12 hours a day, 7 days a week

Number of Tubes

100pcs

Power Used per year in kWh

9,636 kWh

26,280 kWh

16,644 kWh

Power cost per year based on $0.18/kWh

$1,734.48

$4,730.4

$2,995.92

Total CO2 emissions per year in Kg

728kg

2,678kg

1,950kg

Note: Capital costs and maintenance costs which will make potential savings even greater over the lifetime of the LED T8 tubes are not included in the above sheet.

Phone: 86-755-6118-7778 (English Service)    Fax: 86-755-6118-7077
Website:http://www.fobsun.com    Email:sales@fobsun.com
PrintClose